首页 | 本学科首页   官方微博 | 高级检索  
     检索      

采用调幅光波测量无源谐振腔的损耗--实验结果与误差分析
引用本文:梁永辉,胡绍民.采用调幅光波测量无源谐振腔的损耗--实验结果与误差分析[J].应用激光,2000,20(5):219-220.
作者姓名:梁永辉  胡绍民
作者单位:国防科技大学理学院光电工程系,长沙,410073
摘    要:在“小抖动”稳频条件下采用调幅光波测量无源谐振腔损耗 ,给出实验装置及测量结果的误差分析

关 键 词:调幅光波  小抖动  无源谐振腔

Determining the Total Loss of a Passive Resonant Cavity by Amplitude-Modulated Light
Liang Yonghui,Hu Shaomin.Determining the Total Loss of a Passive Resonant Cavity by Amplitude-Modulated Light[J].Applied Laser,2000,20(5):219-220.
Authors:Liang Yonghui  Hu Shaomin
Abstract:The experimental setup and results are given in detail for measuring the total loss of a passive ring resonant cavity with cw amplitudemodulated laser as a probe, where the laser is frequencystabilized to one of the longitudinal modes of the cavity with the socalled dithering method, and error analysis are presented at last.
Keywords:amplitudemodulated laser  dither  passive resonant cavity
本文献已被 CNKI 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号