首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Energy spectra in water for the 6 MV X-ray therapeutic beam generated by Clinac-2300 linac
Institution:1. Department of Nuclear Physics and its Applications, Institute of Physics, Silesian University, 4 Uniwersytecka Str., 40-007 Katowice, Poland;2. Department of Medical Physics, Centre of Oncology, Gliwice Branch, 15 Wybrzeże Armii Krajowej Str., 44-100 Gliwice, Poland;1. INFN - LNF, via Enrico Fermi, 40, 00044 Frascati, Italy;2. University of Rome Tor Vergata - INFN, via della Ricerca Scientifica, 1, 00133 Roma, Italy;3. INFN, Via della Ricerca Scientifica, 1, 00133 Roma, Italy;4. University of Rome La Sapienza, Piazzale Aldo Moro, 2, 00185 Roma, Italy;1. Radiological and Medical Laboratory Sciences, Nagoya University Graduate School of Medicine, Japan;2. Department of Radiological Technology, Nagoya University Hospital, Japan;1. Radiological and Medical Laboratory Sciences, Nagoya University Graduate School of Medicine, Japan;2. Department of Proton Therapy Physics, Nagoya Proton Therapy Center, Nagoya City West Medical Center, Japan
Abstract:There is a lack of extensive data comprising energy spectra of therapeutic beams used in teleradiotherapy, generated by medical linear accelerators. In particular there is a lack of the data for energy spectra in water. However, the spectra in water differ from those in air significantly because of strong photon scattering processes. The aim of this paper was the presentation of the wide range of detailed data for the 6 MV X-ray therapeutic beams from a medical linear accelerator Clinac-2300 by Varian. The presented data were derived by the use of Monte Carlo computer simulations (GEANT4 code). The performed investigations indicate that shapes of the spectra, total number of photon registered in a bin as well as mean energy of the considered beam depend on a depth in water, on a distance from the central-axis of the beam and on a radiation field size. However, shapes of the spectra as well as the beam mean energy does not depend on a bin size, independently of a depth in water and a radiation field whereas total number of photon registered in a bin is related to a bin size. Majority of the presented results were obtained for a cylindrical 1.41 cm3 bin with the radius of 1.5 cm. The obtained data are very useful for the accurate absorbed depth-dose determination particularly outside the reference conditions, for advanced treatment planning systems, for constructors of medical accelerators etc.
Keywords:Energy spectra in water  6 MV therapeutic X-rays
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号