Applicability of continuous-flow fast atom bombardment liquid chromatography-mass spectrometry in bioanalysis. Dextromethorphan in plasma |
| |
Authors: | P Kokkonen W M Niessen U R Tjaden J van der Greef |
| |
Affiliation: | TNO-CIVO Institute, Zeist, The Netherlands. |
| |
Abstract: | Continuous-flow fast atom bombardment (CF-FAB) is an interface for combined liquid chromatography-mass spectrometry using FAB as the ionization method. The applicability of CF-FAB for quantitative bioanalysis was studied for a model compound, dextromethorphan, in plasma samples using conventional high-performance liquid chromatography. The flow-rate reduction was achieved either by splitting or by the phase-system switching approach. The features of both systems are discussed. |
| |