首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Voltammetric study of nifuroxazide at unmodified and Sephadex-modified carbon paste electrodes
Authors:A Radi
Institution:(1) Chemistry Department, Faculty of Science, Mansoura University, 34517 Demiatta, Egypt, EG
Abstract:The electrooxidation of nifuroxazide was investigated by cyclic and differential-pulse voltammetry at carbon paste and Sephadex-modified carbon paste electrodes. Nifuroxazide is irreversibly oxidized at all pH values and gives rise to a well-defined oxidation peak. The modification of the carbon paste surface with Sephadex allowed a preconcentration process to take place for nifuroxazide such that higher sensitivity was achieved compared with the bare surface. The influence of the scan rate, time of accumulation, modifier loading, solution conditions and pH on the adsorptive step at the modified carbon paste electrodes was investigated. The direct determination of the drug in urine is also discussed. Received: 2 June 1998 / Revised: 29 January 1999 / Accepted: 2 February 1999
Keywords:
本文献已被 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号