Abstract:In the paper, the rare earth elements in synthetic samples of europium oxide have been determined by the combination of K coefficient correction method and interference factor correction method with correspoding computer softwares. The results show that the majority of the recoveries are between 90% and 110%, which satisfies the general requirements of quantitative analysis. The method can correct for various interference without matrix match,so it is very practical.