首页 | 本学科首页   官方微博 | 高级检索  
     


Accumulation and trace measurement of chloroquine drug at DNA-modified carbon paste electrode
Authors:Radi A
Affiliation:Department of Chemistry, Faculty of Science (Dumyat), Mansoura University, 34517 Dumyat, Egypt
Abstract:The voltammetric behaviour of chloroquine was investigated at carbon paste and dsDNA-modified carbon paste electrodes in different buffer systems over a wide pH range using cyclic and differential pulse voltammetry. Chloroquine was oxidized in the pH range 2.0-11.0 yielding one irreversible main oxidation peak. A second peak was also observed only in the pH range 5.0-7.0. The modification of the carbon paste surface with dsDNA allowed a preconcentration process to take place for chloroquine such that higher sensitivity was achieved as compared with the bare surface. The response was characterized with respect to solution pH, ionic strength, accumulation time and potential, chloroquine concentration, and other variables. Stripping voltammetric response showed a linear calibration curve in the range 1.0 × 10−7 to 1.0 × 10−5 mol l−1 with a detection limit of 3.0 × 10−8 mol l−1 at the dsDNA-modified electrode. Application of the modified electrode to serum, without sample pretreatment, resulted in good recovery higher than 95% and the higher standard deviation was 3.0%.
Keywords:Voltammetry   Chloroquine   DNA-drug interaction   DNA-modified electrode   Serum analysis
本文献已被 ScienceDirect PubMed 等数据库收录!