首页 | 本学科首页   官方微博 | 高级检索  
     检索      


PVC based 5,10,15,20-tetrakis (4-methoxyphenyl) porphyrinatocobalt(II) membrane potentiometric sensor for arsenite
Authors:Gupta V K  Agarwal S
Institution:Department of Chemistry, Indian Institute of Technology Roorkee, Roorkee 247667, India
Abstract:PVC based membranes of 5,10,15,20-tetrakis(4-methoxyphenyl)porphyrinatocobalt(II) (TMOPP-Co) (I) as electroactive material with dibutyl butyl phosphonate (DBBP), dioctyl phthalate (DOP), 1-chloronaphthalene (CN), tri-n-butyl phosphate (TBP) and tris(2-ethylhexyl) phosphate (TEP) as plasticising solvent mediators have been prepared and tried for arsenite determination. The membrane having a composition 150:5:150 (PVC:I:DBBP) exhibited the best results with linear potential response in the concentration range of 7.9 × 10−5 to 1.0 × 10−1 M of AsO2 with a slope of 28.8 mV/decade. The useful pH range of the sensor is 6.0-10.5. The membrane worked satisfactorily in non-aqueous medium up to 5% (v/v) non-aqueous content. The selectivity coefficient values for mono- and divalent anions indicate good selectivity for arsenite over a large number of anions.
Keywords:PVC  Arsenite  Potentiometric sensor  Chemical sensors
本文献已被 ScienceDirect PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号