Physical design and cooling test of C-band standing wave accelerating tube
Authors:Bai Wei  Xu Zhou  Jin Xiao and Li Ming
Institution:Institute of Applied Electronics, China Academy of Engineering Physics, Mianyang 621900, China
Abstract:The physical design and cooling test of a C-band 2MeV standing wave (SW) accelerating tube are described in this paper. The designed accelerating structure consists of 3-cell buncher and 4-cell accelerating section with a total length of about 163mm,excited with 1MW magnetron. Dynamic simulation presents that about 150mA beam pulse current and 30{\%} capture efficiency can be achieved. By means of nonlinear Gauss fit on electron transverse distribution, the diameter of beam spot FWHM (full width at half maximum of density distribution) is about 0.55mm. Cooling test results of the accelerating tube show that frequencies of cavities are tuned to 5527MHz and the field distribution of bunching section is about 3:9:10.
Keywords:C-band  standing wave  accelerating tube  space charge effect