首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Non-flammable preparative reversed-phase liquid chromatography of recombinant human insulin-like growth factor-I
Authors:Fahrner R L  Lester P M  Blank G S  Reifsnyder D H
Institution:Department of Recovery Sciences, Genentech, Inc., South San Francisco, CA 94080, USA. fahrner.robert@gene.com
Abstract:Acetonitrile is used as an eluent for reversed-phase chromatography. However, because it is a flammable solvent, using acetonitrile on a large scale requires expensive equipment and facilities specially designed for flammable solvents. Using a non-flammable solvent as an eluent eliminates this expense. A method was developed to purify recombinant human insulin-like growth factor I by reversed-phase high-performance liquid chromatography using gradient elution with hexylene glycol, a non-flammable replacement for acetonitrile. The separation produced equivalent yield, purity and throughput as reversed-phase chromatography using elution with acetonitrile.
Keywords:
本文献已被 ScienceDirect PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号