首页 | 本学科首页   官方微博 | 高级检索  
     


Determination of trace elements in uranium oxide by Total Reflection X-ray Fluorescence spectrometry
Affiliation:1. Vinogradov Institute of Geochemistry, SB RAS, 1A Favorsky St., 664033 Irkutsk, Russia;2. Institute of the Earth''s Crust, SB RAS, 128 Lermontov St., 664033 Irkutsk, Russia;3. Irkutsk Institute of Chemistry, SB RAS, 1 Favorsky St., 664033 Irkutsk, Russia;1. Department of Information Engineering, University of Brescia, via Branze, 38, 25123 Brescia, Italy;2. INSTM & Chemistry for Technologies Laboratory, Department of Mechanical and Industrial Engineering, University of Brescia, via Branze, 38, 25123 Brescia, Italy;3. SMART SOLUTIONS s.r.l, via Corfù, 106, 25124 Brescia, Italy;4. Graduate School of Engineering, Osaka City University, Osaka, Japan;5. GNR srl, via Torino 7, 28010 Agrate Conturbia (NO), Italy;6. Elettra-Sincrotrone Trieste, S.S. 14 Km 163.5 in Area Science Park, 34149 Basovizza, Trieste, Italy;1. Department of Physics, International Islamic University, Sector- H-10, Islamabad 44000, Pakistan;2. National Institute of Lasers and Optronics (NILOP), P O Box Nilore, 45650 Islamabad, Pakistan;1. Institute of the Earth''s Crust, SB RAS, 128 Lermontov st., Irkutsk, Russian Federation;2. Sobolev Institute of Geology and Mineralogy SB RAS, 3 Ac. Koptyuga ave., Novosibirsk, Russian Federation
Abstract:A study on the applicability of Total Reflection X-ray Fluorescence for the determination of multielements in trace amounts in U3O8 matrix has been made. The calibration of the Total Reflection X-ray Fluorescence spectrometer and the validation of the method were done using multielement standards. The trace elements present in U3O8 standards and samples were determined after separating the U matrix by solvent extraction using tri-n-butyl phosphate and trioctyl phosphine oxide as extractants. From the aqueous phase the elements K, Ca, Cr, Mn, Fe, Co, Ni, Cu, Zn, Br, Rb, Sr, Y, Zr, Pb and Ba, etc., were determined by Total Reflection X-ray Fluorescence using Ga as an internal standard. An intercomparison of the Total Reflection X-ray Fluorescence determined concentrations of the trace elements specific to nuclear fuel, e.g. Ca, Cr, Mn, Fe, Co, Ni, Cu, Zn in U3O8 standards/samples with certified concentrations for these elements in U3O8 standards and Inductively Coupled Plasma Atomic Emission Spectroscopy determined concentrations in real U3O8 samples was also made. The method shows a precision and accuracy better than 5% (1σ) for most elements in concentration range of ng/mL with a sample size of 10 μL.
Keywords:
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号