首页 | 本学科首页   官方微博 | 高级检索  
     检索      

冷中子三轴谱仪屏蔽体的蒙特卡罗模拟
引用本文:宋建明,尹延朋,李建,刘丽鹃,王虹,孙光爱.冷中子三轴谱仪屏蔽体的蒙特卡罗模拟[J].原子核物理评论,2013,30(1):47-51.
作者姓名:宋建明  尹延朋  李建  刘丽鹃  王虹  孙光爱
作者单位:中国工程物理研究院中子物理学重点实验室和核物理与化学研究所,四川 绵阳 621900
基金项目:国家自然科学基金资助项目(91126001,11105128);中国工程物理研究院科学技术发展基金资助项目(2010A0103002)~~
摘    要:冷中子三轴谱仪( CTAS ) 的屏蔽体对于保障工作人员安全、降低散射大厅本底及提高信噪比具有重要的意义。采用蒙特卡罗程序MCNP5 对谱仪各部分屏蔽体进行了计算,并结合Mcstas 程序确定了CTAS 入口处的中子源,大大提高了计算效率。经过模拟计算和优化表明:单色器后端使用厚350mm、密度4.6 g/cm3 的重混凝土,衔接屏蔽体使用厚300 mm、密度3.6 g/cm3的重混凝土,生物屏蔽采用厚150 mm、密度3.6 g/cm3 的重混凝土可保证屏蔽体外表面的剂量率满足散射大厅的剂量要求。The shielding of Cold neutron Triple-Axis Spectrometer( CTAS ) is important for radiation safety of workers, and reduce the background of scattering hall as well as enhancing the ratio of signal-to-noise. In this study,Monte-Carlo simulation was performed to conduct the calculation on the shielding of CTAS. To increase the calculation efficiency, neutron source was obtained by using Mcstas code. The results indicate that, in the case of heavy concrete ( density 4.6 g/cm3 ) with thickness of 350 mm for the shielding behind the monochromater, and heavy concrete ( density 3.6 g/cm3 ) with thickness of 300 mm for the other monochromater shielding, as well as the heavy concrete ( density 3.6 g/cm3 ) with thickness of 150 mm for biological shielding, the dose rate outside shielding may meet the requirement of national standard of China.

关 键 词:屏蔽    三轴谱仪    中子    γ射线
收稿时间:1900-01-01

Monte-Carlo Simulation for Shielding of Cold Neutron Triple-axis Spectrometer
SONG Jian-ming,YIN Yan-peng,LI Jian,LIU Li-juan,WANG Hong,SUN Guang-ai.Monte-Carlo Simulation for Shielding of Cold Neutron Triple-axis Spectrometer[J].Nuclear Physics Review,2013,30(1):47-51.
Authors:SONG Jian-ming  YIN Yan-peng  LI Jian  LIU Li-juan  WANG Hong  SUN Guang-ai
Institution:Key Laboratory of Neutron Physics and Institute of Nuclear Physics and Chemistry,China Academy of Engineering Physics, Mianyang 621900, Sichuan, China
Abstract:The shielding of Cold neutron Triple-Axis Spectrometer( CTAS ) is important for radiation safety of workers, and reduce the background of scattering hall as well as enhancing the ratio of signal-to-noise. In this study, Monte-Carlo simulation was performed to conduct the calculation on the shielding of CTAS. To increase the calculation efficiency, neutron source was obtained by using Mcstas code. The results indicate that, in the case of heavy concrete ( density 4.6 g/cm3 ) with thickness of 350 mm for the shielding behind the monochromater, and heavy concrete ( density 3.6 g/cm3 ) with thickness of 300 mm for the other monochromater shielding, as well as the heavy concrete ( density 3.6 g/cm3 ) with thickness of 150 mm for biological shielding, the dose rate outside shielding may meet the requirement of national standard of China.
Keywords:shielding  triple-axis spectrometer  neutron  γray
本文献已被 CNKI 万方数据 等数据库收录!
点击此处可从《原子核物理评论》浏览原始摘要信息
点击此处可从《原子核物理评论》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号