首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Comparison of radiometric and non-radiometric methods for uranium determination in groundwater of Punjab,India
Authors:P D B Sonali  K Ajay  J R Priyanka  K Rupali  V K Rajesh  S Rajvir  K S Pradeepkumar
Institution:1. Radiation Safety Systems Division, Bhabha Atomic Research Centre, Trombay, Mumbai, 400085, India
2. Health Physics Division, Bhabha Atomic Research Centre, Trombay, Mumbai, 400085, India
Abstract:Uranium in groundwater samples collected from Punjab state, India was determined using radiometric methods (extractive liquid scintillation and Cerenkov counting). Experimental conditions were optimized by studying the effect of sample pH, quenching and amount of extracting agent added to the scintillation cocktail on recovery of uranium. To ensure the accuracy of results, both radiometric methods were compared with non radiometric method such as adsorptive stripping voltammetry and found to be very good agreement. The distinct advantage of proposed radiometric methods is almost 100 % effective especially extractive liquid scintillation for simultaneous measurement of alpha and beta emitting radionuclides with fast and simple sample preparation.
Keywords:
本文献已被 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号