Rapid high‐performance liquid chromatography–tandem mass spectrometry method for simultaneous measurement of venlafaxine and O‐desmethylvenlafaxine in human plasma and its application in comparative bioavailability study |
| |
Authors: | D. Rajasekhar I. Jaswanth Kumar P. Venkateswarlu |
| |
Affiliation: | 1. Department of Chemistry, SriVenkateswa University, Tirupati‐517502, India;2. Wellquest Clinical research laboratory, Ramanthapur, Hyderabad‐500013, India |
| |
Abstract: | A rapid high‐performance liquid chromatography–tandem mass spectrometry method has been developed and validated for simultaneous measurement of venlafaxine and O‐desmethylvenlafaxine in human plasma using fluoxetine as an internal standard. In the liquid–liquid extraction method, compounds and internal standard were extracted from plasma using methyl tertiary butyl ether as an extraction solvent. The HPLC separation of the analytes was performed on a Zorbax SB‐C18, 50 × 4.6 mm, 5 µm column, using a isocratic elution program using a mobile phase consisting of HPLC‐grade methanol: 5 mm ammonium acetate (80:20 v/v) at a flow‐rate of 1.0 mL/min with a total runtime of 3.0 min. The proposed method has been validated with a linear range of 4–400 ng/mL for venlafaxine and 5–500 ng/mL for O‐desmethyl venlafaxine. The method was applied for a bio‐equivalence study of 75 mg tablets formulation in 32 Indian male healthy subjects under fasting conditions. Copyright © 2009 John Wiley & Sons, Ltd. |
| |
Keywords: | venlafaxine LC‐MS‐MS human plasma |
|
|