Abstract:A rapid and sensitive liquid chromatographic/ion-trap mass spectrometric method has been developed for the simultaneous determination of estriol, alpha-, beta-estradiol, 17alpha-ethynylestradiol and estrone. The substances were extracted from river water samples (typically 250 ml) and cleaned-up using two-stage solid-phase extraction (SPE). 12-(Difluoro-1,3,5-triazinyl)-benz[f]isoindolo-[1,2b][1,3]benzothiazolidine was applied as a derivatizing agent. The recovery for each compounds ranged from 75 to 88% and the repeatability represented as RSDs ranged from 5.6 to 8.4%. Limits of detection (LOD, 3 x S/N) were 67-285 pg/l.