首页 | 本学科首页   官方微博 | 高级检索  
     

光管及窄环隙流道池沸腾换热实验研究
引用本文:孙中宁,阎昌琪,杜泽. 光管及窄环隙流道池沸腾换热实验研究[J]. 工程热物理学报, 2001, 22(4): 485-487
作者姓名:孙中宁  阎昌琪  杜泽
作者单位:哈尔滨工程大学动力工程系
摘    要:本文在常压下以水为工质,对管外及窄环隙流道池沸腾换热进行了可视化实验,结果表明:汽泡扰动并不是沸腾换热系数高的主要原因,液体过冷使核沸腾的换热能力降低,窄隙流道内的沸腾换热机理与普通的大容积沸腾没有明显区别。文中还根据观察和测量到的结果对一些换热现象重新进行了解释。

关 键 词:沸腾换热  池沸腾  窄环隙
文章编号:0253-231(2001)04-0485-03
修稿时间:2000-11-27

EXPERIMENTAL INVESTIGATION OF POOL BOILING HEAT TRANSFER ON BARE TUBE AND IN NARROW ANNULI
SUN Zhong-Ning,YAN Chang-Qi,DU Ze. EXPERIMENTAL INVESTIGATION OF POOL BOILING HEAT TRANSFER ON BARE TUBE AND IN NARROW ANNULI[J]. Journal of Engineering Thermophysics, 2001, 22(4): 485-487
Authors:SUN Zhong-Ning  YAN Chang-Qi  DU Ze
Abstract:Boiling heat transfer from bare tube and in narrow annuli was experimentally studied. The results indicated that the disturbance of vapor bubble is not the major reason why boiling heat transfer coefficient is high, liquid subcooling makes boiling heat transfer capacity decreased, and the mechanism of boiling heat transfer in narrow space has no obvious difference compared with conven- tional pool boiling. Based on the visualization and measurement, some heat transfer phenomena were reinterpreted.
Keywords:boiling heat transfer  pool boiling  narrow annuli