首页 | 本学科首页   官方微博 | 高级检索  
     检索      

Flow—injection Chemiluminescence Determination of Reserpine in Medicine and Biological Fluids with Controlled—Reagent—Release Technology
引用本文:宋正华,张尼.Flow—injection Chemiluminescence Determination of Reserpine in Medicine and Biological Fluids with Controlled—Reagent—Release Technology[J].中国化学,2003,21(2):175-180.
作者姓名:宋正华  张尼
作者单位:DepartmentofChemistry,NorthwestUniversity,Xi’an,Shaanxi710069,China
基金项目:ProjectsupportedbytheNaturalScienceFoundationofEducationCommittee,ShaanxiProvince,China .
摘    要:A sensitive and rapid chemiluminescence(CL) flow injection with controlled-reagent-release technology for the determination of reserpine was proposed.The Cl reagents,luminol and dichromate,uses in this sensor,were all immobilized on anion-exchange resin.Through injection of 100μl of water,the reagents on the anion-ex-change resin column were eluted and in the presence of reserpine ,the CL intensity was decreased,by which reserpine could be sensed.Reserpine was quantified by measuring the decrement of CL intensity,which was observed linear with the logrithm of reserpine concentration in the rage of 1.0-500.0ng/mL,and the limit of detection was 0.4ng/mL(3σ)with a relative standard deviation of less than 3.0?The proposed procedure was applied in the assay of reserpine in pharmaceutical preparation and biological fhuids without any pre-treatment process and with sampling frequencies of 72 times per hour.

关 键 词:利血平  流动注射化学发光测定法  药物分析  生物体液  尿液

Flow-injection Chemiluminescence Determination of Reserpine in Medicine and Biological Fluids with Controlled-Reagent-Release Technology
Song Zheng‐Hua,Zhang Ni.Flow-injection Chemiluminescence Determination of Reserpine in Medicine and Biological Fluids with Controlled-Reagent-Release Technology[J].Chinese Journal of Chemistry,2003,21(2):175-180.
Authors:Song Zheng‐Hua  Zhang Ni
Abstract:A sensitive and rapid chemiluminescence (CL) flow injection with controlled‐reagent‐release technology for the determination of reserpine was proposed. The CL reagents, luminol and dichromate, used in this sensor, were all immobilized on anion‐exchange resin. Through injection of 100 μL of water, the reagents on the anion‐exchange resin column were eluted and in the presence of reserpine, the CL intensity was decreased, by which reserpine could be sensed. Reserpine was quantified by measuring the decrement of CL intensity, which was observed linear with the logarithm of reserpine concentration in the range of 1.0–500.0 ng/mL, and the limit of detection was 0.4 ng/mL (3σ) with a relative standard deviation of less than 3.0%. The proposed procedure was applied in the assay of reserpine in pharmaceutical preparation and biological fluids without any pre‐treatment process and with sampling frequencies of 72 times per hour.
Keywords:reserpine  flow injection  chemiluminescence  medicine  urine
本文献已被 CNKI 维普 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号