首页 | 本学科首页   官方微博 | 高级检索  
     


Determination of paraquat in sunflower seeds by reversed-phase high-performance liquid chromatography
Authors:D C Paschal  L L Needham  Z J Rollen  J A Liddle
Abstract:The herbicide paraquat was determined with extracts from 1-g samples of sunflower seeds. The liquid chromatography procedure utilized a microparticle (10 micron) C18 reversed-phase column and isocratic elution with 27% acetonitrile in water, 10 mM in the sodium salt of octanesulfonic acid. Eluted paraquat was detected at 254 and 280 nm and quantitated by paraquat internal standard peak height ratios. This procedure provided linear working curves over the concentration range of 0-20 microgram/g of paraquat. Recovery of paraquat varied from 89-101%, with an average recovery of 93%. Good agreement was obtained in the comparison of results of the described procedure with those from a well established UV procedure.
Keywords:
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号