首页 | 本学科首页   官方微博 | 高级检索  
     

应用于全氟辛烷磺酸萃取富集的全氟癸基修饰毛细管硅胶整体柱的制备及应用
引用本文:Huang K,Zhou N,Chen B. 应用于全氟辛烷磺酸萃取富集的全氟癸基修饰毛细管硅胶整体柱的制备及应用[J]. 色谱, 2011, 29(10): 957-961. DOI: 10.3724/SP.J.1123.2011.00957
作者姓名:Huang K  Zhou N  Chen B
作者单位:1. 湖南师范大学化学生物学及中药分析教育部重点实验室2. 湖南师范大学
基金项目:国家自然科学基金项目(Nos. 20927005, 20875028, 20080542003, 2008[890])、国家“863”课题(No. 2010AA023001)和湖南省科技计划课题(Nos. 05k009, 2010TT1001).
摘    要:利用溶胶-凝胶法,经过烷氧基硅烷的水解、硅羟基的缩聚、凝胶化、陈化、中孔制备、干燥和表面修饰等步骤制备了全氟癸基修饰的毛细管硅胶整体柱。采用该整体柱对全氟辛烷磺酸(PFOS)进行萃取富集,考察其富集特性和效率,并与传统的C18毛细管硅胶整体柱进行对比。结果表明,全氟癸基修饰毛细管硅胶整体柱(15 cm×75 μm)对PFOS具有更高的吸附量和更好的富集选择性,其平均吸附量可以达到75 ng;样品中PFOS的质量浓度为0.25 mg/L时,富集倍数平均可以达到29倍。此全氟癸基修饰毛细管硅胶整体柱对PFOS具有良好的萃取富集性能,可用于水质中痕量PFOS的萃取富集。

关 键 词:全氟癸基修饰毛细管硅胶整体柱  固相萃取  富集  全氟辛烷磺酸盐
收稿时间:2011-04-18

Reparation and application of perfluorodecyl modified silica monolithic capillary column in extraction and enrichment of perfluorooctane sulfonates
Huang Ke,Zhou Naiyuan,Chen Bo. Reparation and application of perfluorodecyl modified silica monolithic capillary column in extraction and enrichment of perfluorooctane sulfonates[J]. Chinese journal of chromatography, 2011, 29(10): 957-961. DOI: 10.3724/SP.J.1123.2011.00957
Authors:Huang Ke  Zhou Naiyuan  Chen Bo
Affiliation:1. Key Laboratory of Chemical Biology & Traditional Chinese Medicine Research, Ministry of Education, Hunan Normal University, Changsha 410081, China; 2. China National Center for Biotechnology Development, Beijing 100036, China
Abstract:A perfluorodecyl modified silica monolithic capillary column has been prepared by using sol-gel method. The preparation steps included hydrolysis of alkoxy silane, fasculation of silanol, gelation, aging, meso-pore preparation, drying and surface modification. It could be used as a solid phase extraction (SPE) microcolumn for extraction and enrichment of perfluorooctane sulfonate (PFOS). The enrichment characteristics and efficiency of the perfluorodecyl modified monolithic silica capillary column has been investigated and compared with C18 silica monolithic capillary column. The results indicated that the perfluorodecyl modified silica monolithic capillary column ( 15 cm x 75 microm) had a higher adsorption capacity and a better enrichment selectivity for PFOS. The average adsorption capacity of the perfluorodecyl modified silica monolithic capillary column was 75 ng. And when the PFOS mass concentration in sample was 0. 25 mg/L, the enrichment factor was 29-fold in average. Owing to the good performance of the perfluorodecyl modified silica monolithic capillary column, it can be used for the extraction and enrichment of trace PFOS in water to meet the requirements of water quality monitoring and analysis.
Keywords:perfluorodecyl modified silica monolithic capillary column   solid phase extraction (SPE)   enrichment   perfluorooctane sulfonate (PFOS)
本文献已被 PubMed 等数据库收录!
点击此处可从《色谱》浏览原始摘要信息
点击此处可从《色谱》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号