首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Characterization of BSA-fouling of ion-exchange membrane systems using a subtraction technique for lumped data
Institution:1. Institute of Environmental Science, Engineering and Management, Industrial University of Ho Chi Minh City, Ho Chi Minh City, Viet Nam;3. Division of Nephrology, Department of Internal Medicine, Chang Gung Memorial Hospital, Linkou, Taiwan;4. Department of Safety, Health and Environmental Engineering, Ming Chi University of Technology, Taishan, New Taipei City 24301, Taiwan
Abstract:Electrical impedance spectroscopy (EIS) techniques were used to gain insight into BSA fouling of the Neosepta CMX and AMX ion-exchange membranes (IEMs). EIS characterizations were made at concentrations above 0.1 M KCl because the conductance of the IEMs was higher than that of bulk solutions of concentration below 0.1 M KCl. Spectra, expressed in terms of dispersions of the conductance and capacitance with frequency, provided an enhanced indication of IEM fouling during separation processes. Bulk conductance measurements of the solution alone, membrane immersed in solution and fouled membrane immersed in solution showed good agreement with general theoretical predictions. Strong dispersions in capacitance were observed below 1 kHz for each of these configurations. Differences in the dispersions arising from fouling were identified by subtracting the impedance of the solution from those of unfouled and fouled IEMs in solution. The conductance and capacitance dispersions of fouled IEMs decreased with the accumulation of the BSA fouling layer on the surface.
Keywords:
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号