首页 | 本学科首页   官方微博 | 高级检索  
     


Analysis of ofloxacin in plasma samples by high-performance liquid chromatography
Authors:M. A. Garcia  C. Solans  A. Calvo  M. Royo  E. Hernandez  R. Rey  M. A. Bregante
Affiliation:(1) Department of Analytical Chemistry, Veterinary Faculty, University of Zaragoza, Miguel Servet 177, 50013 Zaragoza, Spain;(2) Department of Pharmacology and Physiology, Veterinary Faculty, University of Zaragoza, Miguel Servet 177, 50013 Zaragoza, Spain
Abstract:Summary A sensitive HPLC method has been developed for determination of ofloxacin (OFL) in biological fluids. Sample preparation was performed by adding phosphate buffer (pH 7.4, 0.1m) then extraction with trichloromethane. OFL and the internal standard, sarafloxacin (SAR), were separated on a reversed-phase column with aqueous phosphate solution-acetonitrile, 80∶20, as mobile phase. The fluorescence of the column effluent was monitored at λex 338 and λem 425 nm. The retention times were 2.66 and 4.24 min for OFL and SAR, respectively, and the detection and quantitation limits were 8 and 15 ng mL−1, respectively. Plots of response against ofloxacin concentration were linear in the range 8 to 2000 ng mL−1. Recovery was 92.9% for OFL.
Keywords:Column liquid chromatography  Fluorescence detection  Ofloxacin in plasma
本文献已被 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号