首页 | 本学科首页   官方微博 | 高级检索  
     检索      

电感耦合等离子体质谱法测定甜味剂中重金属元素
引用本文:聂西度,梁逸曾,符靓,谢华林.电感耦合等离子体质谱法测定甜味剂中重金属元素[J].光谱学与光谱分析,2012,32(10):2838-2841.
作者姓名:聂西度  梁逸曾  符靓  谢华林
作者单位:1. 中南大学化学化工学院,湖南 长沙 410083
2. 湖南工学院材料与化学工程学院,湖南 衡阳 421002
3. 长江师范学院化学化工学院,重庆 涪陵 408100
基金项目:国家自然科学基金项目,重庆市自然科学基金项目,重庆市教委科学技术研究项目
摘    要:采用微波消解-八极杆碰撞/反应池(ORS)-电感耦合等离子体质谱仪(ICP-MS)测定甜味剂中Cr,Co,Ni,Cu,As,Cd,Sn,Sb,Hg,Pb等十种重金属元素的含量。样品用硝酸+双氧水消解后,试液直接用ICP-MS法进行测定。应用ORS技术,有效地消除了多原子离子对待测元素的干扰,选用45Sc,89Y,115In和209Bi等元素为内标混合液校正基体效应和信号漂移,确定了实验的最佳测定条件。结果表明,该方法对十种待测元素的检出限在0.003~0.038 μg·L-1之间,加标回收率在93.0%~106.6%之间,相对标准偏差(RSD)≤3.4%。方法简便、快速、准确,可以用于食品甜味剂质量控制和安全评价。

关 键 词:电感耦合等离子体质谱法  八极杆碰撞/反应池  甜味剂  重金属元素  
收稿时间:2012-03-18

Direct Determination of Heavy Metal Elements in Sweeteners by Inductively Coupled Plasma Mass Spectrometry
NIE Xi-du , LIANG Yi-zeng , FU Liang , XIE Hua-lin.Direct Determination of Heavy Metal Elements in Sweeteners by Inductively Coupled Plasma Mass Spectrometry[J].Spectroscopy and Spectral Analysis,2012,32(10):2838-2841.
Authors:NIE Xi-du  LIANG Yi-zeng  FU Liang  XIE Hua-lin
Institution:1. School of Chemistry and Chemical Engineering, Central South University, Changsha 410083, China2. College of Material and Chemical Engineering, Hunan Institute of Technology, Hengyang 421002, China3. College of Chemistry and Chemical Engineering, Yangtze Normal University, Fuling 408100, China
Abstract:An analysis method of microwave digestion and inductively coupled plasma-mass spectrometry (ICP-MS) with octopole reaction system (ORS) was established for the determination of 10 heavy metal elements including Cr, Co, Ni, Cu, As, Cd, Sn, Sb, Hg and Pb in sweetener. Samples were decomposed by HNO3 and H2O2 followed by dilution with ultrapure water then the above 10 heavy metal elements in the solution were analyzed directly by ICP-MS. The use of ORS can eliminate the interference of polyatomic ions dramatically. 45Sc, 89Y, 115In and 209Bi as internal standard elements were used to compensate matrix effect and signal drift. The optimum conditions for the determination was tested and discussed. Under the optimal conditions, the detection limits of the 10 elements were in the range of 0.003~0.038 μg·L-1, the recovery of the samples was in the range of 93.0%~106.6% and the relative standard deviation(RSD)≤3.4%, which showed that the method was very precise. The technique was applied for the quality control and safety evaluation of sweetener.
Keywords:Inductively Coupled Plasma Mass Spectrometry(ICP-MS)  Octopole reaction system(ORS)  Sweetener  Heavy metal elements  
本文献已被 CNKI 万方数据 等数据库收录!
点击此处可从《光谱学与光谱分析》浏览原始摘要信息
点击此处可从《光谱学与光谱分析》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号