Simultaneous enantioselective determination of fenbuconazole and its main metabolites in soil and water by chiral liquid chromatography/tandem mass spectrometry
Authors:Li Yuanbo  Dong Fengshou  Liu Xingang  Xu Jun  Li Jing  Kong Zhiqiang  Chen Xiu  Song Wencheng  Wang Yunhao  Zheng Yongquan
Institution:Institute of Plant Protection, Chinese Academy of Agricultural Sciences, Key Laboratory of Pesticide Chemistry and Application, Ministry of Agriculture, Beijing 100193, China.
Abstract:A novel and sensitive method was developed for the simultaneous determination of fenbuconazole and its main metabolites enantioselectively using chiral liquid chromatography coupled with tandem mass spectrometry. The separation and determination were performed using reversed-phase chromatography on a cellulose chiral stationary phase, a Chiralcel OD-RH (150 mm×4.6 mm) column, under isocratic conditions at 0.5 mL/min flow rate. The effects of three cellulose-based columns and three amylose-based columns on the separation were also investigated. The elution orders of the eluting enantiomers were identified by an optical rotation detector. The QuEChERS (acronym for Quick, Easy, Cheap, Effective, Rugged and Safe) method and solid-phase extraction (SPE) were used for the extraction and clean-up of the soil and water samples, respectively. Parameters including the matrix effect, linearity, precision, accuracy and stability were evaluated. Under optimal conditions, the mean recoveries for all enantiomers from the soil samples were 82.5-104.1% with 2.7-9.5% intra-day relative standard deviations (RSD) and 5.7-11.2% inter-day RSD at 5, 25 and 50 μg/kg levels; the mean enantiomer recoveries from the water samples were 81.8-104.6% with 2.6-11.4% intra-day RSD and 5.3-10.4% inter-day RSD at 0.25, 0.5 and 2.5 μg/L levels. Coefficients of determination R2≥0.9991 were achieved for each enantiomer in the soil and water matrix calibration curves within the range of 1.0-125 μg/L. The limits of detection (LOD) for all enantiomers in the soil and water were less than 0.8 μg/kg, whereas the limit of quantification (LOQ) did not exceed 2.5 μg/kg. The results of the method validation confirm that this proposed method is convenient and reliable for the enantioselective determination of the enantiomers of fenbuconazole and its main metabolites in soil and water.
Keywords:Fenbuconazole  Metabolite  Enantioselectivity  LC–MS/MS  Chirality  Enantiomers
本文献已被 ScienceDirect PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号