首页 | 本学科首页   官方微博 | 高级检索  
     

高效液相色谱-高锰酸钾氧化化学发光法测定水中的痕量苯二酚
引用本文:范顺利,张立科,魏彦林,林金明. 高效液相色谱-高锰酸钾氧化化学发光法测定水中的痕量苯二酚[J]. 色谱, 2006, 24(2): 148-151
作者姓名:范顺利  张立科  魏彦林  林金明
作者单位:1.Henan Key Laboratory for Environmental Pollution Control, College of Chemistry and Environmental Sciences, Henan Normal University, Xinxiang 453007, China; 2.State Key Laboratory of Environmental Chemistry and Ecotoxicology, Research Center for Eco-Environmental Sciences, the Chinese Academy of Sciences, Beijing 100085, China
基金项目:中国科学院资助项目;中国科学院方向性项目
摘    要:基于酸性介质中甲酸对高锰酸钾-苯二酚氧化发光反应的增敏作用建立了高效液相色谱-化学发光柱后检测苯二酚的新方法。优化了高锰酸钾-苯二酚氧化发光反应及高效液相色谱分离苯二酚的条件,用甲醇-0.1 mmol/L β-环糊精水溶液(体积比为30∶70) 作为流动相可实现对水中3种苯二酚异构体的分离,且能与高锰酸钾-苯二酚氧化化学发光反应条件很好地偶合。对所测定的苯二酚异构体,方法的线性范围达两个数量级;以信噪比为3测得邻、间、对苯二酚的检出限(n=3)分别为:5.2,4.7,3.2 μg/L,对质量浓度均为0.10 mg/L的3种苯二酚混合溶液连续测定11次,邻、间、对苯二酚的相对标准偏差分别为2.8%,3.4%,6.5%。将该方法与固相萃取技术相结合,对河水中的痕量苯二酚进行了测定,加标回收率为92.1%~95.4%。

关 键 词:苯二酚  高锰酸钾  高效液相色谱  固相萃取  化学发光检测  
文章编号:1000-8713(2006)02-0148-04
收稿时间:2005-03-14
修稿时间:2005-03-14

Determination of Dihydroxybenzenes Using High Performance Liquid Chromatography with Acidic Potassium Permanganate Chemiluminescence
FAN Shunli,ZHANG Like,WEI Yanlin,LIN Jin-Ming. Determination of Dihydroxybenzenes Using High Performance Liquid Chromatography with Acidic Potassium Permanganate Chemiluminescence[J]. Chinese journal of chromatography, 2006, 24(2): 148-151
Authors:FAN Shunli  ZHANG Like  WEI Yanlin  LIN Jin-Ming
Affiliation:1.Henan Key Laboratory for Environmental Pollution Control, College of Chemistry and Environmental Sciences, Henan Normal University, Xinxiang 453007, China; 2.State Key Laboratory of Environmental Chemistry and Ecotoxicology, Research Center for Eco-Environmental Sciences, the Chinese Academy of Sciences, Beijing 100085, China
Abstract:A sensitive, selective and simple post-column chemiluminescence (CL) detection method for simultaneously determining catechol, resorcinol, hydroquinone has been developed based on high performance liquid chromatography (HPLC) coupled with CL detection using reaction of dihydroxybenzenes with acidified potassium permanganate solution with the enhancing effect of formic acid. The optimal conditions for the CL detection and HPLC separation were achieved. Dihydroxybenzene isomers were baseline separated at column temperature of 25 degrees C using a mobile phase of methanol-0.1 mmol/L beta-cyclodextrin aqueous solution (30/70, v/v) with an isocratic elution program and the mobile phase matched well the CL detection. For all compounds, the linear ranges of the CL detection were about two orders of magnitude. The detection limits were 3.2 microg/L for hydroquinone, 4.7 microg/L for resorcinol and 5.2 microg/L for catechol. Combining with solid phase extraction, the proposed method was successfully applied to the determination of dihydroxybenzenes in river water. The recoveries for the three dihydroxybenzenes were 92.1%-95.4%.
Keywords:high performance liquid chromatography(HPLC)  chemiluminescence(CL) detection  potassium permanganate  solid phase extraction(SPE)  dihydroxybenzenes
本文献已被 CNKI 维普 万方数据 等数据库收录!