首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Dependence of mark size on STM pulse voltage in heat-assisted magnetic probe recording on a cobalt–nickel–platinum thin film
Institution:1. State Key Laboratory of Electronic Thin Films and Integrated Devices, University of Electronic Science and Technology of China, Chengdu 610054, PR China;2. Department of Applied Physics, University of Electronic Science and Technology of China, Chengdu 610054, PR China
Abstract:This paper presents a method of heat-assisted magnetic probe recording on perpendicular medium. Electrical current from scanning tunneling microscope (STM) is employed as the major heating source. Recording medium is a strongly-coupled CoNi/Pt multilayered film. Pulses with amplitude of 3–7 V and duration of 200 ns were applied between the STM tip and the recording medium. Experiments show that magnetic marks with an average size of 184 nm were formed for voltages above 4 V. A model is built to simulate the formation of magnetic domains in the processing of probe-based magnetic recording. Simulation results agree with experiments well.
Keywords:
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏