摘    要:液晶光阀实验中一般是用带布氏窗的He-Ne激光器作为读出光光源,本文分析了普通He-Ne激光、半导体激光、卤素灯等常见光源在液晶光阀实验中应用的可能性和各自特点并进行了实验验证.

关 键 词:液晶光阀 光源 偏振分光棱镜
文章编号:1005-4642(2005)10-0045-04
收稿时间:2005-04-26
修稿时间:2005-04-26

Effect of light source on the experiment of liquid crystal light valve
SUN Lei, CHEN Shao-wen, MA Xiu-fang. Effect of light source on the experiment of liquid crystal light valve[J]. Physics Experimentation, 2005, 25(10): 45-48
Authors:SUN Lei   CHEN Shao-wen   MA Xiu-fang
Affiliation:Physics Department, Fudan University, Shanghai 200433, China
Abstract:He-Ne laser with Brewster windows is usually used as a light source in of liquid crystal light valve. The properties and potential application of He-Ne laser, laser and halogen lamp in the same experiment are analyzed experimentally. the experiment semiconductor