Neutron electric dipole moment measurement with a buffer gas comagnetometer
Authors:Yasuhiro Masuda  Koichiro Asahi  Kichiji Hatanaka  Sun-Chan Jeong  Shinsuke Kawasaki  Ryohei Matsumiya  Kensaku Matsuta  Mototsugu Mihara  Yutaka Watanabe
Institution:1. High Energy Accelerator Research Organization, 1-1 Oho, Tsukuba, Ibaraki 305-0801, Japan;2. Tokyo Institute of Technology, 2-12-1 Ookayama, Meguro-ku, Tokyo 152-8550, Japan;3. RCNP, Osaka University, 10-1 Mihogaoka, Ibaraki, Osaka 567-0047, Japan;4. Graduate School of Science, Osaka University, 1-1 Machikaneyama, Toyonaka, Osaka 560-0043, Japan
Abstract:A neutron EDM measurement with a comagnetometer is discussed. For magnetometry, polarized xenon atoms are injected into a cylindrical cell where a cylindrically symmetric magnetic field and an electric field are applied for the EDM measurement. The geometric phase effect (GPE), which originates from particle motion in a magnetic field gradient, is analyzed in terms of the Dyson series. The motion of the xenon atom is largely suppressed because of a small mean free path. The field gradient is controlled by means of NMR measurements, where the false effect of Earth?s rotation is removed. As a result, the GPE is reduced below 10−28e cm1028e cm.
Keywords:EDM  Magnetometer  NMR
本文献已被 ScienceDirect 等数据库收录!