基于常规组合光谱仪下的LIBS快速铅检测研究
引用本文:姜琛昱,张贵忠,傅饶,陆茵菲,汪淼,姚建铨.基于常规组合光谱仪下的LIBS快速铅检测研究[J].光谱学与光谱分析,2010,30(6):1652-1656.
作者姓名:姜琛昱  张贵忠  傅饶  陆茵菲  汪淼  姚建铨
作者单位:1. 天津大学精密仪器与光电子工程学院,天津 300072
2. 光电信息技术科学教育部重点实验室(天津大学),天津 300072
3. 中国科学院苏州生物医学工程技术研究所(筹),江苏 苏州 215163
基金项目:国家自然科学基金,国家重点基础研究发展(973计划)项目,天津市科委基金,苏州医工所青年引导基金 
摘    要:激光诱导击穿光谱技术(LIBS)是一种实时在线的无损检测技术,可以满足工农业生产以及生物医学领域检测仪器高速化和自动化的要求。采用波长为1 064 nm的调Q脉冲为激发光源,常规组合光谱仪中的CCD为探测器,以纯铅、玻璃、焊锡等为样品,在建立的LIBS实验装置上对样品的铅含量进行定性定量检测。通过对不同铅含量样品的检测,初步确定了在自行搭建的全国产化系统下,铅的检测极限为0.0074%,定量检测误差多在4%左右,2~3 min即可完成定性定量分析。实验结果表明,采用光栅光谱仪和非增强型CCD完全可以实现LIBS的快速铅检测,其检测极限和检测精度基本达到了商用标准,并大大降低了实验装置成本,对LIBS在国内同行的相关实用化研究具有一定的借鉴作用。

关 键 词:激光诱导击穿光谱    快速检测  常规光谱仪  CCD  
收稿时间:2009-08-02

Investigation on Rapid Detection of Lead by LIBS Based on Common Spectrograph
JIANG Chen-yu,ZHANG Gui-zhong,FU Rao,LU Yin-fei,WANG Miao,YAO Jian-quan.Investigation on Rapid Detection of Lead by LIBS Based on Common Spectrograph[J].Spectroscopy and Spectral Analysis,2010,30(6):1652-1656.
Authors:JIANG Chen-yu  ZHANG Gui-zhong  FU Rao  LU Yin-fei  WANG Miao  YAO Jian-quan
Institution:1. College of Precision Instrument and Optoelectronics Engineering,Tianjin University,Tianjin 300072, China2. Key Laboratory of Optoelectronics Information and Technical Science Ministry of Education(Tianjin University),Tianjin 300072,China3. Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Sunzhou 215163, China
Abstract:In the present paper, the lead concentrations of samples including glass, soldering tin and so on were determined by LIBS based on a Nd∶YAG Q-switched pulse laser with wavelength 1 064 nm as an exciting source and CCD in common spectrograph as the detector. The pulse energy on the surface of samples is about 95 mJ and the pulse width is 12 ns. By the detection of different samples, the detection limit of lead in samples was found to be 0.007 4% and the maximum relative standard deviation of quantitative analysis was about 4.0% based on the LIBS system of the instruments all made in China. The quantitative analysis can be done in two or three minutes and will spend one minute finishing the process by software in the future. The results suggest that the accuracy of determination of lead meets the challenge of quantitative analysis and the CCD can displace the very expensive ICCD as detector. The feasibility and low cost of the method, which uses common spectrometer and CCD to realize the LIBS detection, is proved by the result and our investigation will be beneficial to the LIBS application.
Keywords:CCD