CHF of forced convection boiling in uniformly heated vertical tubes: Experimental study of HP-regime by the use of refrigerant 12
Authors:Y Katto  S Yokoya
Institution:Department of Mechanical Engineering, University of Tokyo, Hongo, Bunkyo-yu, Tokyo, Japan
Abstract:For the critical heat flux in HP-regime, that is high-pressure regime, almost no data having been published for fluids other than water, an experimental study is attempted on R-12 boiling in 5- and 3-mm dia. and 1000-mm long tubes. Critical heat flux qc is measured in the range of pressure p = 19.6?34.3 bar (vapor-to-liquid density ratio ρGρL = 0.109?0.306), mass velocity G = 1100?9000 kg/m2s, and inlet subcooling enthalpy ΔHi= 0?65 kJ/kg. Depending on the condition of G and ΔHi, CHF takes place with natures which can be divided into two categories, regular and anomalous. For regular CHF, critical condition is detected first at the exit end of heated tube and a linear qc ? ΔHi relationship holds, whereas anomalous CHF initiates its critical condition upstream of the tube exit and exhibits involved relationship between qc and ΔHi. Experimental data of regular CHF are found to agree fairly well with the predictions of two different generalized correlations proposed recently by Katto and by Shah respectively although some systematic differences proper to each correlation exist.