Rapid method for the determination of radiostrontium in milk |
| |
Authors: | S Brun S Bessac D Uridat B Boursier |
| |
Institution: | (1) Laboratoire d"Etude et de Recherche sur l"Hygiène et la Qualité des Aliments de l"Agence Française de Sécurité Sanitaire des Aliments, AFSSA/LERHQA/CEN-RAD, 10 rue Pierre Curie, 94704 Maisons Alfort, France |
| |
Abstract: | A radiochemical procedure comprising ion chromatography for preconcentration, oxalate precipitation for alkali/alkaline earth separation, strontium specific extraction chromatography with a crown ether for calcium/strontium separation, carbonate precipitation for counting on a low background proportional counter, provides a simple, rapid (48 h) and effective method for radiostrontium determination in emergency situation in milk. The separation scheme gives a strontium recovery rate of 62% and an empiric relative standard deviation of 11%. The detection limit for 500 ml milk and 3600-second counting time is 0.090 Bq.l-1. |
| |
Keywords: | |
本文献已被 SpringerLink 等数据库收录! |
|