首页 | 本学科首页   官方微博 | 高级检索  
     


A chemiluminescence sensor for the determination of hydrogen peroxide
Authors:Azra Tahirovi?  Amira ?opra  Enisa Omanovi?-Mikli?anin  Kurt Kalcher
Affiliation:a Institute for Chemistry, Karl-Franzens University, Universitaetsplatz 1, Graz, Austria
b Faculty of Forestry, University of Sarajevo, Zagrebacka 20, Sarajevo, Bosnia and Herzegovina
c Faculty of Natural Science, University of Sarajevo, Zmaja od Bosne 33, Sarajevo, Bosnia and Herzegovina
d Faculty of Agriculture, University of Sarajevo, Zmaja od Bosne 8, Sarajevo, Bosnia and Herzegovina
Abstract:A chemiluminescence one-shot sensor for hydrogen peroxide is described. It is prepared by immobilization of cobalt chloride and sodium lauryl sulphate in hydroxyethyl cellulose matrix cast on a microscope cover glass. Luminol, sodium phosphate and the sample are mixed before use and applied on the membrane by a micropipette. The calibration graph is linear in the range 20-1600 μg/L, and the detection limit of the method (3σ) is 9 μg/L. A relative standard deviation of 4.5% was obtained for 100 μg/L H2O2 (n = 11). The sensor has been applied successfully to the determination of hydrogen peroxide in rainwater.
Keywords:Chemiluminescence   Sensors   Hydrogen peroxide   Rainwater
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号