Laboratory for Analytical Chemistry, Ghent University, Belgium
Studiecentrum voor Kernenergie MOL, Belgium
Abstract:
Submicrogram amounts of silver have been determined in lead by neutron-activation analysis. The activity of the 110Ag isotope was measured by following the decay of the 0·66-MeV gamma ray. Reproducibility was generally better than 10%. The smallest amount of silver determined was approximately 0·02 μg. The analyses were completed within 15 min.