首页 | 本学科首页   官方微博 | 高级检索  
     检索      

重量法测定毒重石中碳酸钡含量
引用本文:严海,杜顺林,吴光耀,赵卫东,曹重,段家华.重量法测定毒重石中碳酸钡含量[J].中国无机分析化学,2020,10(6):33-36.
作者姓名:严海  杜顺林  吴光耀  赵卫东  曹重  段家华
作者单位:武昆股份玉溪新兴钢铁有限公司,昆钢科创中心,武昆股份玉溪新兴钢铁有限公司 技术中心,云南 玉溪 653100,昆钢科创中心,武昆股份玉溪新兴钢铁有限公司 技术中心,云南 玉溪 653100,武昆股份玉溪新兴钢铁有限公司 技术中心,云南 玉溪 653100
摘    要:为消除毒重石中少量碳酸钙、不溶性硅酸盐和硫酸钡等杂质对碳酸钡分析结果的影响,本文采用盐酸消解试样,慢速过滤消除硫酸钡及硅酸盐干扰;滤液在PH=4.5的弱酸环境中,与重铬酸钾溶液反应生成铬酸钡沉淀,过滤消除钙离子干扰,通过重量法测定铬酸钡含量间接换算碳酸钡含量。按本文所述检测方法测得毒重石中碳酸钡含量相对标准偏差RSD均小于1%,加标回收率99.26%~103.00%,满足日常分析要求。

关 键 词:毒重石  重量法  碳酸钡  重铬酸钡  干扰消除
收稿时间:2020/1/16 0:00:00
修稿时间:2020/2/1 0:00:00

Determination of barium carbonate in witherite by gravimetric method
yanhai,DU Shunlin,WU Guangyao,ZHAO Weidong,CAO Chong and DUAN Jiahua.Determination of barium carbonate in witherite by gravimetric method[J].Chinese Journal of Inorganic Analytical Chemistry,2020,10(6):33-36.
Authors:yanhai  DU Shunlin  WU Guangyao  ZHAO Weidong  CAO Chong and DUAN Jiahua
Institution:Technical Center of Yuxi Xinxing Steel Co., Ltd.,Kungang Science and Technology Innovation Center,Technical Center of Yuxi Xinxing Steel Co., Ltd. Yuxi, Yunnan 653100, China,Kungang Science and Technology Innovation Center,Technical Center of Yuxi Xinxing Steel Co., Ltd. Yuxi, Yunnan 653100, China,Technical Center of Yuxi Xinxing Steel Co., Ltd. Yuxi, Yunnan 653100, China
Abstract:In order to eliminate the influence of a small amount of impurities such as calcium carbonate, insoluble silicate and barium sulfate on the analysis results of barium carbonate, hydrochloric acid is used to digest the sample and slow filtration is used to eliminate the interference of barium sulfate and silicate. In the alkaline environment with pH = 4.5, the filtrate reacts with potassium dichromate solution to form barium chromate precipitation and filtration is used to eliminate the interference of calcium ion. The content of barium chromate is determined by gravimetric method Indirect conversion of barium carbonate content. The RSD of barium carbonate in witherite is less than 1% and the recovery of standard addition is 99.26% ~ 103.00%, which meets the requirements of daily analysis.
Keywords:Witherite  Gravimetric method  Barium carbonate  Barium dichromate  Interference cancellation