Luminescent Sensor for Carbonate Ion Based on Lanthanide(III) Complexes of 1,4,7,10-Tetraazacyclododecane-1,4,7-Triacetic Acid (DO3A)
Authors:Jakub Vaněk  P?emysl Lubal  Petr Hermann  Pavel Anzenbacher Jr
Institution:1. Department of Chemistry, Faculty of Science, Masaryk University, Kotlá?ská 2, 611 37, Brno, Czech Republic
2. Central European Institute of Technology (CEITEC), Masaryk University, Kamenice 5, 625 00, Brno, Czech Republic
3. Department of Inorganic Chemistry, Faculty of Science, Charles University, Hlavova 2030, 128 40, Prague, Czech Republic
4. Department of Chemistry and Center for Photophysical Sciences, Bowling Green State University, Bowling Green, OH, 43403, USA
Abstract:Lanthanide(III) complexes of 1,4,7,10-tetraazacyclododecane-1,4,7-triacetic acid (H3DO3A) are suggested as sensors for sensitive luminescence-based determination of a carbonate anion. Thermodynamic study of association of Eu(H2O)2(DO3A)] with bidentate anionic ligands using luminescence spectroscopy reveals an affinity order CO 3 2? > oxalate2? > picolinate? > phthalate2? ≈ citrate3?; presumably as a consequence of an increasing chelate ring size. The ternary Eu(DO3A)(picolinate)]? and Tb(DO3A)(picolinate)]? complexes show improved photophysical properties due to the antenna effect of the picolinate anion. High quenching effect of carbonate anion and, to a lesser extent also oxalate, enables construction of a linear calibration plot utilizing optimized experimental conditions (e.g. c LnL?=?0.1 mM, c picolinate?=?2–5 mM, pH?=?7.4, λ exc?=?286 nm, etc.) for carbonate determination in solution. Both sensors show a comparable sensitivity and the detection limit of about 0.4 mM. In order to improve the photophysical properties of Ln(III) sensor by shift of excitation wavelength about 40 nm to VIS range, the isoquinoline-3-carboxylic acid (IQCA) as antenna ligand was employed instead of picolinic acid. The analysis of commercial samples of European mineral waters was carried out and they were compared to the results obtained by capillary isotachophoresis to confirm there is no inherent (systematic) error to the present analysis. The Ln(III) sensor with IQCA is recommended since it has a better robustness than that with picolinate. The present analytical method is simple and rapid, and it is useful for sensitive determination of bicarbonate/carbonate concentration in water samples under aerobic conditions.
Keywords:
本文献已被 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号