Soft contact lens biosensor for in situ monitoring of tear glucose as non-invasive blood sugar assessment
Authors:Chu Ming Xing  Miyajima Kumiko  Takahashi Daishi  Arakawa Takahiro  Sano Kenji  Sawada Shin-ichi  Kudo Hiroyuki  Iwasaki Yasuhiko  Akiyoshi Kazunari  Mochizuki Manabu  Mitsubayashi Kohji
Affiliation:a Department of Advanced Sciences and Technology for Biomedical Sensors, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University, 1-5-45 Yushima, Bunkyo-ku, Tokyo 113-8549, Japan
b Department of Biomedical Devices and Instrumentation, Institute of Biomaterials and Bioengineering, Tokyo Medical and Dental University, 2-3-10 Kanda-Surugadai, Chiyoda-ku, Tokyo 101-0062, Japan
c Department of Ophthalmology and Visual Science, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University, 1-5-45 Yushima, Bunkyo-ku, Tokyo 131-8519, Japan
d Department of Chemistry and Materials Engineering, Faculty of Chemistry, Materials and Bioengineering, Kansai University, 3-3-35 Yamate-chou, Suita-city, Osaka 564-8680, Japan
e Department of Organic Materials, Institute of Biomaterials and Bioengineering, Tokyo Medical and Dental University, 2-3-10 Kanda-Surugadai, Chiyoda-ku, Tokyo 101-0062, Japan
Abstract:A contact lens (CL) biosensor for in situ monitoring of tear glucose was fabricated and tested. Biocompatible 2-methacryloyloxyethyl phosphorylcholine (MPC) polymer and polydimethyl siloxane (PDMS) were employed as the biosensor material. The biosensor consists of a flexible Pt working electrode and a Ag/AgCl reference/counter electrode, which were formed by micro-electro-mechanical systems (MEMS) technique. The electrode at the sensing region was modified with glucose oxidase (GOD). The CL biosensor showed a good relationship between the output current and glucose concentration in a range of 0.03-5.0 mM, with a correlation coefficient of 0.999. The calibration range covered the reported tear glucose concentrations in normal and diabetic patients. Also, the CL biosensor was applied to a rabbit for the purpose of tear glucose monitoring. The basal tear glucose was estimated to 0.11 mM. Also, the change of tear glucose induced by the change of blood sugar level was assessed by the oral glucose tolerance test. As a result, tear glucose level increased with a delay of 10 min from blood sugar level. The result showed that the CL biosensor is expected to provide further detailed information about the relationship between dynamics of blood glucose and tear glucose.
Keywords:Biosensor   Tear   Glucose   Non-invasive   Continuous monitoring   Bioinstrumentation