首页 | 本学科首页   官方微博 | 高级检索  
     

Simultaneous determination of naphazoline and pyridoxine in eye drops using excitation–emission matrix fluorescence coupled with second-order calibration method based on alternating trilinear decomposition algorithm
引用本文:Hui Xia,Hai-Long Wu,Hui-Wen Gu,Xiao-Li Yin,Huan Fang,Ru-Qin Yu. Simultaneous determination of naphazoline and pyridoxine in eye drops using excitation–emission matrix fluorescence coupled with second-order calibration method based on alternating trilinear decomposition algorithm[J]. 中国化学快报, 2015, 26(12): 1446-1449. DOI: 10.1016/j.cclet.2015.07.015
作者姓名:Hui Xia  Hai-Long Wu  Hui-Wen Gu  Xiao-Li Yin  Huan Fang  Ru-Qin Yu
作者单位:State Key Laboratory of Chemo/Biosensing and Chemometrics, College of Chemistry and Chemical Engineering, Hunan University, Changsha 410082, China
基金项目:The authors would like to acknowledge the financial supports from the National Natural Science Foundation of China (No. 21175041), the National Basic Research Program of China (No. 2012CB910602), and the Foundation for Innovative Research Groups of NSFC (No. 21221003).
摘    要:A novel method is developed for the direct determination of naphazoline hydrochloride(NAP) and pyridoxine hydrochloride(VB6) in commercial eye drops. By using excitation–emission matrix(EEM)fluorescence coupled with second-order calibration method based on the alternating trilinear decomposition(ATLD) algorithm, the proposed approach can achieve quantitative analysis successfully even in the presence of unknown and uncalibrated interferences. The method shows good linearity for NAP and VB6 with correlation coefficients greater than 0.99. The results were in good agreement with the labeled contents. To further confirm the feasibility and reliability of the proposed method, the same batch samples were analyzed by multiple reaction monitoring(MRM) based on LC–MS/MS method.T-test demonstrated that there are no significant differences between the prediction results of the two methods. The satisfactory results obtained in this work indicate that the use of the second-order calibration method coupled with the EEM is a promising tool for industrial quality control and pharmaceutical analysis due to its advantages of high sensitivity, low-cost and simple implementation.


Simultaneous determination of naphazoline and pyridoxine in eye drops using excitation-emission matrix fluorescence coupled with second-order calibration method based on alternating trilinear decomposition algorithm
Hui Xia,Hai-Long Wu,Hui-Wen Gu,Xiao-Li Yin,Huan Fang,Ru-Qin Yu. Simultaneous determination of naphazoline and pyridoxine in eye drops using excitation-emission matrix fluorescence coupled with second-order calibration method based on alternating trilinear decomposition algorithm[J]. Chinese Chemical Letters, 2015, 26(12): 1446-1449. DOI: 10.1016/j.cclet.2015.07.015
Authors:Hui Xia  Hai-Long Wu  Hui-Wen Gu  Xiao-Li Yin  Huan Fang  Ru-Qin Yu
Affiliation:State Key Laboratory of Chemo/Biosensing and Chemometrics, College of Chemistry and Chemical Engineering, Hunan University, Changsha 410082, China
Abstract:A novel method is developed for the direct determination of naphazoline hydrochloride (NAP) and pyridoxine hydrochloride (VB6) in commercial eye drops. By using excitation-emission matrix (EEM) fluorescence coupled with second-order calibration method based on the alternating trilinear decomposition (ATLD) algorithm, the proposed approach can achieve quantitative analysis successfully even in the presence of unknown and uncalibrated interferences. The method shows good linearity for NAP and VB6 with correlation coefficients greater than 0.99. The results were in good agreement with the labeled contents. To further confirm the feasibility and reliability of the proposed method, the same batch samples were analyzed by multiple reaction monitoring (MRM) based on LC-MS/MS method. T-test demonstrated that there are no significant differences between the prediction results of the two methods. The satisfactory results obtained in this work indicate that the use of the second-order calibration method coupled with the EEM is a promising tool for industrial quality control and pharmaceutical analysis due to its advantages of high sensitivity, low-cost and simple implementation.
Keywords:Excitation-emission matrix fluorescence  Second-order calibration method  Alternating trilinear decomposition method  Naphazoline hydrochloride  Vitamin B6  