Acoustic energy relations in Mudejar-Gothic churches |
| |
Authors: | Zamarreño Teófilo Girón Sara Galindo Miguel |
| |
Affiliation: | Departamento de Física Aplicada II, Universidad de Sevilla, ETS de Arquitectura IUCC, Avda. Reina Mercedes 2, 41012-Sevilla, Spain. teofilo@us.es |
| |
Abstract: | Extensive objective energy-based parameters have been measured in 12 Mudejar-Gothic churches in the south of Spain. Measurements took place in unoccupied churches according to the ISO-3382 standard. Monoaural objective measures in the 125-4000 Hz frequency range and in their spatial distributions were obtained. Acoustic parameters: clarity C80, definition D50, sound strength G and center time Ts have been deduced using impulse response analysis through a maximum length sequence measurement system in each church. These parameters spectrally averaged according to the most extended criteria in auditoria in order to consider acoustic quality were studied as a function of source-receiver distance. The experimental results were compared with predictions given by classical and other existing theoretical models proposed for concert halls and churches. An analytical semi-empirical model based on the measured values of the C80 parameter is proposed in this work for these spaces. The good agreement between predicted values and experimental data for definition, sound strength, and center time in the churches analyzed shows that the model can be used for design predictions and other purposes with reasonable accuracy. |
| |