首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Low power measurements of the quality factor of an open resonator with stepped mirrors
Authors:A Perrenoud  M Q Tran  B Isaak  S Alberti and P Muggli
Institution:(1) Centre de Recherches en Physique des Plasmas Association Euratom-Confédération Suisse, Ecole Polytechnique Fédérale de Lausanne, 21, Av. des Bains, CH-1007 Lausanne, Switzerland
Abstract:Open resonators in which both mirrors have a central step have been predicted to exhibit mode selection properties. This is advantageous for the design of quasi-optical gyrotrons. Quality factor measurements of a 36 cm resonator at 120 GHz are presented and compared with theory. Although the effect of the step is clearly seen, the quality factor Q of the resonator is lower than that predicted.
Keywords:Open resonator  quasi-optical gyrotrons  mode selection  stepped mirrors
本文献已被 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏