A time-of-scan laser triangulation technique for distance measurements
Authors:V Lombardo  T Marzulli  C Pappalettere  P Sforza  
Institution:a Centro Laser Scrl, Str. Prov. per Casamassima km 3, 70010, Valenzano (BA), Italy;b Politecnico di Bari—DIMeG -Viale Japigia, 182-70126, Bari, Italy
Abstract:This paper reports the development of an electro-optic device for relative distance measurement. The time-of-scan triangulation technique has been used as measurement principle and a rotating mirror employed as beam deflection system. A calibration technique is needed to calculate the geometrical parameters of the system. The device has an accuracy of 100 μm, a working distance of 20 cm and a range of 10 mm. The accuracy obtained depends on the instability of the rotation speed of the mechanical scanner that affects the measurement of the scanning time.