摘    要:拉曼光谱作为研究物质结构的一个强有力工具,被广泛应用于水环境物质的检测,近年在深海原位探测中也得到应用.文章针对水下拉曼光谱探测的需要,设计了用于水的O-H振动拉曼信号抑制的低通滤光片,经过计算,边缘为指数形式的低通滤光片可较好的满足需要,而且通过实际采用的低通滤光片的实验证明,采用低通滤光片后水的O-H振动拉曼信号得...

关 键 词:拉曼光谱  水下原位  水拉曼信号抑制  低通滤光片

Water Raman spectrum suppression with low-pass filter in underwater in-situ Raman spectroscopy
Guo Jin-Jia,Liu Zhi-Shen. Water Raman spectrum suppression with low-pass filter in underwater in-situ Raman spectroscopy[J]. Spectroscopy and Spectral Analysis, 2011, 31(9): 2428-2430
Authors:Guo Jin-Jia  Liu Zhi-Shen
Affiliation:GUO Jin-jia1,2,LIU Zhi-shen2 1.Key Laboratory of Submarine Geoscience and Explorting Technology of Ministry of Education,Ocean University of China,Qingdao 266100,China 2.Ocean Remote Sensing Institute,Qingdao 266003,China
Abstract:As a powerful tool for studying chemical structures, Raman spectroscopy has been used in aquatic environments in-situ measurement widely, and has been used in deep sea research recently. For underwater in-situ detection, O-H vibration Raman peak of water is inherent and strong compared with other dissolved matter's Raman signals. When the authors want to get a good SNR Raman signal of dissolved matter by increasing detection time, O-H vibration Raman peak of water will get to saturation easily, which influences other Raman signal's detection. In the present paper, a specially designed short-pass optical filter was used for suppression of water's O-H vibration Raman peak. The authors calculated the suppression effect of short-pass optical filter with linear and exponential edges. The simulation shows that exponential edge filter has better performance and can suppress water's O-H vibration Raman peak effectively. The experiment also proves the calculation results. With the suppression optical filter, the intensity of water's O-H vibration Raman signal and other dissolved matters' become similar. And the influence of suppression optical filter on other dissolved matters' Raman signal is little. So the suppression optical filter is feasible for in-situ underwater Raman spectroscopy.
Keywords:Raman spectroscopy  Underwater  in-situ  Water's Raman spectrum suppression  Short-pass optical filter  