Apparent diffusion coefficient of line scan diffusion image in normal prostate and prostate cancer—comparison with single-shot echo planner image |
| |
Authors: | Takeshi Yoshizako Akihiko WadaKoji Uchida Shinji HaraMikio Igawa Hajime KitagakiStephan E. Maier |
| |
Affiliation: | a Department of Radiology, Shimane University Faculty of Medicine, 00693-8501, 89-1 Enya Izumo, Japanb Department of Urology, Shimane University Faculty of Medicine, 00693-8501, 89-1 Enya Izumo, Japanc Department of Radiology, Brigham and Women''s Hospital, Harvard Medical School, Boston, MA 02115, USA |
| |
Abstract: | PurposeThis retrospective study was designed to evaluate the apparent diffusion coefficient (ADC) of line scan diffusion images (LSDI) in normal prostate and prostate cancer. Single-shot echo planner images (SS-EPI) were used for comparison.Materials and MethodsTwenty prostate tumors were examined by conventional MRI in 14 patients prior to radical prostatectomy. All patients were examined with a 1.5-T MR imager (Signa CV/i ver. 9.1 GE Medical System Milwaukee, WI, USA). Diffusion-weighted MR imaging (DWI) using LSDI was performed with a pelvic phased-array coil, with b values of 5 and 800 s/mm2. DWI using SS-EPI was performed with a body coil, with b values of 0 and 800 s/mm2. The ADCs of each sequence for 14 normal prostate and 20 prostate cancers were histopathologically assessed. Signal-to-noise ratio (SNR) on DWI was estimated and compared for each sequence.ResultsThe mean ADCs (±S.D.) of normal peripheral zones (PZ), transition zones (TZ) and cancer (in 10−3 mm2/s) that used LSDI were 1.42±0.12, 1.23±0.10 and 0.79±0.19, respectively. Those that used SS-EPI were 1.76±0.26, 1.38±0.20 and 1.05±0.27, respectively. Using unpaired t test (P<.05), we found a significant difference in each sequence between normal tissue (both PZ and TZ) and the cancer. Paired t test (P<.05) also registered a significant difference between LSDI and SS-EPI. Mean SNR for DWI using LSDI was 16.49±5.03, while the DWI using SS-EPI was 18.85±9.26. The difference between the SNR of each sequence was not statistically significant by paired t test.ConclusionWe found that ADCs using LSDI and SS-EPI showed similar tendencies in the same patients. However, in all regions, LSDI ADCs had smaller standard deviations than SS-EPI ADCs. |
| |
Keywords: | Diffusion-weighted magnetic resonance imaging Apparent diffusion coefficient Line scan diffusion image Single-shot echo planner image Prostate |
本文献已被 ScienceDirect 等数据库收录! |
|