Electrochemical Ammonia Gas Sensing in Nonaqueous Systems: A Comparison of Propylene Carbonate with Room Temperature Ionic Liquids
Authors:Xiaobo Ji  Craig?E Banks  Debbie?S Silvester  Leigh Aldous  Christopher Hardacre  Richard?G Compton
Institution:1. Physical and Theoretical Chemistry Laboratory, Oxford University, South Parks Road, Oxford OX1 3QZ, UK;2. School of Biomedical and Natural Sciences, Nottingham Trent University, UK;3. School of Chemistry and Chemical Engineering/QUILL, Queen's University Belfast, Belfast, Northern Ireland BT9 5AG, UK
Abstract:First, the direct and indirect electrochemical oxidation of ammonia has been studied by cyclic voltammetry at glassy carbon electrodes in propylene carbonate. In the case of the indirect oxidation of ammonia, its analytical utility of indirect for ammonia sensing was examined in the range from 10 and 100 ppm by measuring the peak current of new wave resulting from reaction between ammonia and hydroquinone, as function of ammonia concentration, giving a sensitivity 1.29×10?7 A ppm?1 (r2=0.999) and limit‐of‐detection 5 ppm ammonia. Further, the direct oxidation of ammonia has been investigated in several room temperature ionic liquids (RTILs), namely 1‐butyl‐3‐methylimidazolium tetrafluoroborate (C4mim] BF4]), 1‐butyl‐3‐methylimidazolium trifluoromethylsulfonate (C4mim] OTf]), 1‐Ethyl‐3‐methylimidazolium bis(trifluoromethylsulfonyl)imide (C2mim] NTf2]), 1‐butyl‐3‐methylimidazolium bis(trifluoromethylsulfonyl)imide (C4mim] NTf2]) and 1‐butyl‐3‐methylimidazolium hexafluorophosphate (C4mim] PF6]) on a 10 μm diameter Pt microdisk electrode. In four of the RTILs studied, the cyclic voltammetric analysis suggests that ammonia is initially oxidized to nitrogen, N2, and protons, which are transferred to an ammonia molecule, forming NHequation image via the protonation of the anion(s) (A?). However, in C4mim] PF6], the protonated anion was formed first, followed by NHequation image . In all five RTILs, both HA and NHequation image are reduced at the electrode surface, forming hydrogen gas, which is then oxidized. The analytical ability of this work has also been explored further, giving a limit‐of‐detection close to 50 ppm in C2mim] NTf2], C4mim] OTf], C4mim] BF4], with a sensitivity of ca. 6×10?7 A ppm?1 (r2=0.999) for all three ionic liquids, showing that the limit of detection was ca. ten times larger than that in propylene carbonate since ammonia in propylene carbonate might be more soluble in comparison with RTILs when considering the higher viscosity of RTILs.
Keywords:Ammonia oxidation  Propylene carbonate  Room temperature ionic liquids  Gas sensing  Electrochemistry
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号