Positronium annihilation in silica aerogel studied by a positron age-momentum correlation technique
Authors:WANG Dan-Ni  ZHANG Lan-Zhi  WANG Bao-Yi  YU Run-Sheng  ZHANG Zhi-Ming  LI Dao-Wu  WEI Long
Abstract:A high-performance positron age-momentum correlation (AMOC) spectrometer was newly developed.The counting rate is increased up to 200 cps much larger than the value 20 cps reported by other international groups.And at the same time,the time resolution still keeps at the international level of 220 ps.Furthermore,positronium (Ps) annihilation in silica aerogel was investigated by AMOC,which indicates:(1) Ps annihilation between the grains dominantly undergoes pick-off process and spin conversion from o-Ps to p-Ps;(2) Annealing below 400 ℃ changes the grain surface conditions,i.e.the desorption of hydrogen and the decrease of the defect centers concentration.
Keywords:positron age-momentum correlation  positronium formation  positron states  silica aerogel
本文献已被 万方数据 等数据库收录!
点击此处可从《中国物理C(英文版)》浏览原始摘要信息
点击此处可从《中国物理C(英文版)》下载免费的PDF全文