摘    要:针对碘量在一定范围内变化对激光功率影响不敏感,采用碘量变化的方法,通过对大量的250mmol/s列管式射流氧发生器的出光实验的分析,得到了激光功率波形随碘量变化的实验规律.这一实验结果可用于根据功率波形变化来调节最佳碘量.并对其机理进行了理论分析.

关 键 词:COIL  激光功率波形  碘发生器
文章编号:1001-4322(2000)0-0059-04
修稿时间:2000年10月25

The relation between the flow-rate of iodine and the curve of laser power versus time in COIL
LIU Wan-fa,XU Wen-gang,ZHAO Tong,SANG Feng-ting.The relation between the flow-rate of iodine and the curve of laser power versus time in COIL[J].High Power Laser and Particle Beams,2000,12(Z1):59-62.
Authors:LIU Wan-fa  XU Wen-gang  ZHAO Tong  SANG Feng-ting
Abstract:The experimental rule for the variation of laser power versus the flow-rate of iodine was obtained on a COIL device using a jet-type singlet oxygen generator with pipe-array, in which the flow-rate of Cl 2 was 250mmol/s. Theoretical analysis was given for the phenomenon. The results can help us to optimize the flow-rate of iodine.
Keywords:COIL  iodine flow-rate  laser power  