Determination of the dose-depth distribution of proton beam using resazurin assay in vitro and diode laser-induced fluorescence detection |
| |
Authors: | Kim Min Jung Pal Sukdeb Tak Yu Kyung Lee Kyeong-Hee Yang Tae Keun Lee Su-Jae Song Joon Myong |
| |
Affiliation: | a Research Institute of Pharmaceutical Sciences and College of Pharmacy, Seoul National University, Seoul 151-742, South Korea b Applied Imaging Research Group, Korea Electrotechnology Research Institute, Gyeonggi-Technopark, 1271-11, Ansan 426-901, Korea c Korea Institute of Radiological and Medical Sciences (KIRAMS), 215-4, Gongneung-dong, Nowon-gu, Seoul 139-706, South Korea d Laboratory of Radiation Experimental Therapeutics, Korea Institute of Radiological and Medical Sciences, Seoul, South Korea |
| |
Abstract: | In this study the dose-depth distribution pattern of proton beams was investigated by inactivation of human cells exposed to high-LET (linear energy transfer) protons. The proton beams accelerated up to 45 MeV were horizontally extracted from the cyclotron, and were delivered to the cells acutely through a home made prototype over a range of physical depths (in the form of a variable water column). The biological systems used here were two in vitro cell lines, including human embryonic kidney cells (HEK 293), and human breast adenocarcinoma cell line (MCF-7). Cells were exposed to unmodulated proton beam radiation at a dose of 50 Gy similar to that used in therapy. Resazurin metabolism assay was investigated for measurement of cell response to irradiation as a simple and non-destructive assay. In the resazurin reduction test the non-fluorescent probe dye is reduced to pink and highly fluorescent resorufin. The dose-depth distribution of proton beam obtained based on the highly sensitive laser-induced fluorometric determination of resorufin was found to coincide well with the data collected using conventional film based dosimetry. The resazurin method yielded data comparable with the optical micrographs of the irradiated cells, showing the least cell survival at the measured Bragg-peak position of 10 mm. In addition, fused silica capillary was used as a sample container to increase the probability for irradiated laser beam to probe and excite resorufin in small sample volume of the capillary. The developed method has the potential to serve as a non-destructive, sample-thrifty, and time saving tool to realize more realistic, practical dose-depth distribution of proton beam compared to conventional in vitro cell viability assessment techniques. |
| |
Keywords: | Proton beam Dose-depth distribution Bragg-peak Resazurin Resorufin Laser-induced fluorescence |
本文献已被 ScienceDirect PubMed 等数据库收录! |
|