首页 | 本学科首页   官方微博 | 高级检索  
     检索      


A method for the determination of theophylline in serum by isotope dilution mass spectrometry
Authors:F Susanto  S Humfeld  C M Niederau and H Reinauer
Institution:(1) Department of Clinical Biochemistry, Diabetes Research Institute, Heinrich-Heine-University, Auf'm Hennekamp 65, W-4000 Düsseldorf 1, Federal Republic of Germany
Abstract:Summary A method for the determination of theophylline in human serum by the isotope dilution/mass spectrometric technique is described. As an internal standard labelled (1,3-15N2-2-13C)theophylline is added to the serum sample. The analyte and internal standard are extracted with chloroform/2-propanol (90:10) and converted to the trimethylsilyl derivatives. The extraction and silylation procedures are checked by adding theophylline and internal standard in various concentrations to blank serum and determining the recovery. The trimethylsilyl derivatives of labelled and non-labelled theophylline are separated and detected by GC-MS with the mass spectrometer set to m/z 252 and 255. The amounts of theophylline in the serum are calculated from the isotope ratios measured by selected ion monitoring. The accuracy, precision and recovery of this GC-MS method are presented and discussed. The coefficient of variation determined from duplicate samples was less than 2.5%. The detection limit was 10 ng/ml at a signal-to-noise ratio of 3:1.Part of the work was presented at the 32th Kongreß der Deutschen Gesellschaft für Laboratoriumsmedizin, Frankfurt 1991
Keywords:
本文献已被 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏