A high-sensitive amperometric hydrogen peroxide biosensor based on the immobilization of hemoglobin on gold colloid/L-cysteine/gold colloid/nanoparticles Pt-chitosan composite film-modified platinum disk electrode |
| |
Authors: | Yang Gan Yuan Ruo Chai Ya-Qin |
| |
Institution: | Chongqing Key Laboratory of Analytical Chemistry, College of Chemistry and Chemical Engineering, Southwest University, Chongqing 400715, China. |
| |
Abstract: | A hemoglobin (Hb)/gold colloid (nano-Au)/L-cysteine (L-cys)/nano-Au/nanoparticles Pt (nano-Pt)-chitosan (CHIT) composite film-modified platinum disk electrode (abbreviated to modified electrode) has been prepared to construct a biosensor for determination of H(2)O(2). The electrochemical characteristics of the biosensor were studied by cyclic voltammetry and chronoamperometry. The modified process was characterized by electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV). The morphologies of different composite film were investigated with scanning electron microscopy (SEM) and the element of composite film was investigated with X-ray photoelectron spectroscopy (XPS). Analytical parameters such as pH and temperature were also studied. The linear range for the determination of H(2)O(2) is 1.4 x 10(-7) to 6.6 x 10(-3)mol/L with a detection limit of 4.5 x 10(-8)mol/L (S/N=3). The sensor achieved 95% of the steady-state current within 10s. The sensor exhibited high sensitivity (17.62 microA/(mmol L)), selectivity and stability. The method is applied to the determination of H(2)O(2) with satisfactory results. |
| |
Keywords: | |
本文献已被 ScienceDirect PubMed 等数据库收录! |