首页 | 本学科首页   官方微博 | 高级检索  
     


Application of Net Analyte Signal Standard Addition Method (NASSAM) for Simultaneous Determination of Lead and Tin by Differential Pulse Polarography
Authors:Karim Asadpour‐Zeynali  Mir Reza Majidi  Javad Vallipour  Samira Jafari
Affiliation:Department of Analytical Chemistry, Faculty of Chemistry, University of Tabriz, Tabriz 51666 16471, Iran
Abstract:Differential pulse polarography was used for simultaneous determination of Sn2+ and Pb2+. But there is a problem for simultaneous determination and it is high overlapped DPPs of mentioned cations that their determination is impossible in the presence of each other, so multivariate calibration methods as chemomatrics methods were used for this determination. There are some disadvantageous for multivariate calibration methods that can be solved by a new and simple method called net analyte signal standard addition method. This method has some advantages, such as: the use of a full voltammogram, realization in a single step, therefore it does not require calibration and prediction steps and only a few measurements are required for the determination.
Keywords:Net analyte signal standard addition method  Simultaneous determination  Differential pulse polarography  Lead  Tin
设为首页 | 免责声明 | 关于勤云 | 加入收藏