High-performance liquid chromatographic method with ultraviolet detection for the determination of dapsone and its hydroxylated metabolite in human plasma
Authors:Kwadijk S  Toraño J Sastre
Affiliation:Pharmaceutical and Clinical Toxicological Laboratory, Department of Clinical Pharmacy E0-127, Academic Medical Center, University of Amsterdam, Meibergdreef 9, 1105 AZ Amsterdam, The Netherlands.
Abstract:A validated high-performance liquid chromatographic method with ultraviolet detection for the quantitative determination of dapsone (4,4'-diaminodifenyl sulfone, DDS) and a metabolite, hydroxylaminodapsone (4-amino-4-hydroxylaminodiphenyl sulfone, DDS-NOH), in human plasma is described. Human plasma was deproteinized with acetone and the clear supernatant solution after centrifugation was evaporated to dryness under a gentle stream of nitrogen at 70 degrees C. The residue was dissolved in a mixture of HPLC eluent and acetone (18:5 v/v) and an aliquot of this solution (50 microL) was injected onto the HPLC column. Dapsone, hydroxylaminodapsone and diazoxide as internal standard, were separated within 10 min by isocratic elution with water:acetonitrile:glacial acetic acid:triethylamine (80:20:1.0:0.5 by volume) as eluent. Detection was by ultraviolet at the wavelength of 295 nm. The within-day repeatability coefficients of variation were 3-5% for dapsone (0.301-20.0 mg/L, n = 5) and 3-5% for hydroxylaminodapsone (0.0948-6.32 mg/L, n = 5), whereas the between-day repeatability coefficients of variation were 3-8% (0.301-20.0 mg/L, n = 5) for dapsone and 4-10% for hydroxylaminodapsone (0.0948-6.32 mg/L, n = 5). The mean recoveries -were 92-107% (0.301-20.0 mg/L, n = 2), 80-82% (0.0948-6.32 mg/L, n = 2) and 88% (0.0200 mg/mL, n = 5), for dapsone, hydroxylaminodapsone and diazoxide, respectively. The average correlation coefficient of the calibration curve was 0.99988 (n = 5) for dapsone at a concentration range of 0.301-20.0 mg/L, whereas the average correlation coefficient of the hydroxylaminodapsone calibration curve was 0.99981 (n = 5) at a concentration range of 0.0948-6.32 mg/L. The limits of detection were 0.00200 and 0.0470 mg/L for dapsone and hydroxylaminodapsone, respectively. The method is suitable for drug level monitoring and for pharmacokinetic studies.
Keywords:
本文献已被 PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号