Quantitative determination of sauchinone in rat plasma by liquid chromatography-mass spectrometry |
| |
Authors: | Xu Chun-lei Chen Jian-wei Ju Wen-zheng Liu Shi-jia Chen Yong Chen Zhi-peng Xue Ping Chen Hong-jiang Li Xiang |
| |
Affiliation: | College of Pharmacy, Nanjing University of Chinese Medicine, Nanjing, People's Republic of China. |
| |
Abstract: | A rapid, sensitive and specific method using liquid chromatography with tandem mass spectrometric detection (LC‐MS) was developed for the analysis of sauchinone in rat plasma. Di‐O‐methyltetrahydrofuriguaiacin B was used as internal standard (IS). Analytes were extracted from rat plasma by liquid–liquid extraction using ethyl acetate. A 2.1 mm i.d. × 150 mm, 5 µm, Agilent Zorbax SB‐C18 column was used to perform the chromatographic analysis. The mobile phase was methanol–deionized water (80:20, v/v). The chromatographic run time was 7 min per injection and the flow‐rate was 0.2 mL/min. The tandem mass spectrometric detection mode was achieved with electrospray ionization interface in positive‐ion mode (ESI+). The m/z ratios [M + Na]+, m/z 379.4 for sauchinone and m/z 395.4 for IS were recorded simultaneously. Calibration curve were linear over the range of 0.01–5 µg/mL. The lowest limit of quantification was 0.01 µg/mL. The intra‐day and inter‐day precision and accuracy of the quality control samples were 2.94–9.42% and 95.79–108.05%, respectively. The matrix effect was 64.20–67.34% and the extraction recovery was 93.28–95.98%. This method was simple and sensitive enough to be used in pharmacokinetic research for determination of sauchinone in rat plasma. Copyright © 2011 John Wiley & Sons, Ltd. |
| |
Keywords: | sauchinone LC‐MS rat plasma pharmacokinetics |
本文献已被 PubMed 等数据库收录! |
|