Ambient imaging mass spectrometry by electrospray ionization using solid needle as sampling probe
Authors:Lee Chuin Chen  Kentaro Yoshimura  Zhan Yu  Rikiya Iwata  Hajime Ito  Hiroaki Suzuki  Kunihiko Mori  Osamu Ariyada  Sen Takeda  Takeo Kubota  Kenzo Hiraoka
Affiliation:1. Clean Energy Research Center, University of Yamanashi, Takeda 4‐3‐11, Kofu, 400‐8511, Japan;2. Department of Anatomy and Cell Biology, Faculty of Medicine, University of Yamanashi, Shimo‐Kateau 1110, Chuo, 409‐3898, Japan;3. College of Chemistry and Biology, Shenyang Normal University, Shenyang, 110034, China;4. Arios Inc., Musashino 3‐2‐20, Akishima, Tokyo, 196‐0021, Japan;5. Department of Epigenetic Medicine, Faculty of Medicine, University of Yamanashi, Shimo‐Kateau 1110, Chuo, 409‐3898, Japan
Abstract:Although being an atmospheric pressure ion source, electrospray ionization (ESI) has rarely been used directly for ambient imaging mass spectrometry because the sample has to be introduced as liquid solution through the capillary. Instead of capillary, probe electrospray ionization (PESI), which has been developed recently, uses a solid needle as the sampling probe, as well as the electrospray emitter, and has been applied not only for liquid solutions but also for the direct sampling on wet samples. Biological tissues are composed of cells that contain 70–90% water, and when the surface is probed by the needle tip, the biological fluid adhering to the needle can be electrosprayed directly or assisted by additional solvent added onto the needle surface. Here, we demonstrate ambient imaging mass spectrometry of mouse brain section using PESI, incorporated with an auxiliary heated capillary sprayer. The solvent vapor generated from the sprayer condensed on the needle tip, re‐dissolving the adhered sample, and at the same time, providing an indirect means for needle cleaning. The histological sections were prepared by fixation using paraformaldehyde, and the spatial analysis was automated by maintaining an equal sampling depth into the sample in addition to raster scan. Phospholipids and galactosylceramides were readily detected from the mouse brain section in the positive ion mode, and were mapped with 60 µm lateral resolution to form mass spectrometric images. Copyright © 2009 John Wiley & Sons, Ltd.
Keywords:imaging mass spectrometry  electrospray ionization  ambient sampling probe  solid needle  mouse brain section
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号